Customization: | Available |
---|---|
Function: | Pressure Regulating, Flow Control |
Installation: | Plate |
Still deciding? Get samples of US$ 457/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Hydraulic | |||
Installation | Optional, preferably horizontal | ||
Nominal size | 6 | 10 | |
Weight (kg) | 4WRA... 2X | 2 | 6.6 |
Nominal flow Qvnom at △p = 10 bar (L/min) | 7, 15, 26 | 30, 60 | |
Hysteresis (%) | ≤5 | ||
Reversal span (%) | ≤1 | ||
Response sensitivity (%) | ≤ 0.5 | ||
Max.operating pressure | Ports A,B,P (bar) | 350 | |
Port T (bar) | 210 | ||
Pressure fluid | Mineral oil(HL,HLP) to DIN 51524 | ||
Other pressure fluids on request! | |||
Ambient air temperature range (ºC) | 4WRA...2X | -20°C to 70°C(-4°F to 158°F) | |
Viscosity range (mm2/s) | 20to 380(preferably 30 to 46) | ||
Fluid Cleanliness Class | NAS1638 class9 or ISO 4406 class 20/18/15 |
Electrical | ||||
1)Solenoid data | ||||
Voltage type | DC | |||
Command value signal for 4WRA | ±10Vor4~20mA | |||
Max.current per solenoid (A) | 2.5 | 1.5 | 0.8 | |
Solenoid coil resistance (Ω) | Cold value at 20°C | 2 | 4.8 | 19.5 |
Max.warm value | 3 | 7.2 | 28.8 | |
Duty (%) | ED100% | |||
Max.coil temperature (ºC) | 150 | |||
Valve protection to EN60529 | IP 65 | |||
2) Control electronics | ||||
Amplifier | 4WRA...2X | VT-VSPA2-...- 2X | ||
Supply voltage (V) | Nominal voltage | 24 | ||
Lower limiting value | 21/22(4WRA) | |||
Upper limiting value | 35 | |||
Amplifier power consumption (A) | Imax | <1.8 | ||
Impulse current | 3 |